100 g
1 .. 373 K
ambient
0 - 35 T
ANSx150/LT x-Scanner made from Titanium
large range open loop x-scanner
This piezo driven scanner is optimized for high precision scanning in one direction over a large scan range, even at cryogenic temperatures.
The positioner is designed for temperatures between 1K..373 K.
Titanium is the material of choice for our cryogenic nanopositioners, as it is light, nonmagnetic, and has a coefficient of expansion matching the piezo and other elements of the drive for reliable low temperature performance.
Specifications
For a detailed definition of used terms and descriptions please visit our Nanopositioners Glossary
Size and Dimensions | |
---|---|
footprint; height | 24 mm x 24 mm; 9 mm |
maximum installation space | 24 mm x 24 mm; 9 mm |
weight | 18 g |
Materials | |
positioner body | titanium |
actuator | PZT ceramics |
connecting wires | insulated twisted pair, copper |
Coarse Positioning Mode | |
typical actuator capacitance @ 300 K [µF] | 11.1 |
Fine Positioning Mode | |
fine linear positioning range @ 300 K | 80 µm |
fine linear positioning range @ 4 K | 125 µm |
fine positioning resolution | sub-nm |
typical actuator capacitance fine @ 300 K | 11.1 µF |
typical actuator capacitance fine @ 4 K | 2.6 µF |
input DC voltage range @ 300 K | 0 - 60 V |
input DC voltage range @ 4 K | +/- 120V |
* | scan range depends on environment |
Load (@ ambient conditions) | |
maximum load | 100 g |
General Specifications | |
environment | /LT |